2-Octyl Cyanoacrylate Synthesis Essay

3.1. General

Paraformaldehyde, phosphorus pentoxide and acetone (Panreac, Barcelona, Spain), toluene (QUINSA, D.F., Mexico), piperidine hydrochloride (Acros Organics, Geel, Belgium), monohydrated p-toluene sulfonic acid (APTS), and tetrahydrofuran (THF) (Merck Schuchardt OHG, Hohenbrunn, Germany), hydroquinone Analar (BDH Chemicals Ltd, Poole, England), and ethanol (96%) (national production) were used without further purification. n-Butyl cyanoacetate (Probus, Barcelona, Spain) was distilled previous to its use. The Fourier transform IR spectra were measured using a JASCO FT/IR-4100 spectrometer and KBr tablets. 1H-NMR spectra were obtained at 250 MHz using a Bruker 250 Avance NMR spectrometer with tetramethylsilane as reference. Microwave radiation was carried out using a microwave Milestone’s START System. The BCA synthesis occurs fundamentally in two steps (Equations (1) and (2)). To check the reproducibility of the methods, three experiments were carried out applying both heating sources in the cases of “direct” and “indirect synthesis”.

3.2. Direct Synthesis of BCA Using an Oil Bath

n-Butyl cyanoacetate (50 mL, 0.3517 mol), paraformaldehyde (11.689 g, 0.3 mol), piperidine hydrochloride (0.3 g, 0.002 mol) and toluene (37 mL, 0.3 mol) were mixed in a three-neck round-bottom flask. The mixture was heated to about 130 °C under stirring, while distilling out the water and toluene. When the distillation stopped, the mechanical stirring was removed and the rest of the water-toluene mixture extracted under reduced pressure. The reaction ended after about 75 min, when distillation stopped. The formed water was measured. Phosphorus pentoxide (1.4218 g, 0.01 mol), hydroquinone (0.4405 g, 0.004 mol) and APTS (0.4517 g, 0.002 mol) were then added to the product, which was pyrolyzed for one hour at 109 °C between 0.15–1 mm Hg. Hydroquinone (0.1767 g, 0.002 mol) and APTS (0.0961 g, 0.0005 mol) were then added to the obtained monomer, which was purified by distillation. APTS (0.02 g, 0.0001 mol) was added to the final product (36 mL, 67%). The distillation equipment used in the last two stages had been previously treated with a 20% APTS solution. Figure 1 shows all these stages.

BCA: IR (KBr): 3124, 2960–2878, 2235, 1735, 1612, 1461, 1283-1187, 1386 cm−1. 1H-NMR (acetone-d6, 250 MHz): δ 0.96 (3H, m3, J = 7.23 Hz, (CH2)3-CH3), 1.44 (2H, m6, J = 8.03 Hz, (CH2)2-CH2-CH3), 1.72 (2H, m5, J = 7.76 Hz, CH2-CH2-CH2-CH3), 4.29 (2H, m3, J = 7.23 Hz, O-CH2-(CH2)2-CH3), 6.63 (1H, s,=CH ), 7.06 (1H, s, =CH).

1. Toriumi DM, O'Grady K. Surgical tissue adhesives in otolaryngology-head and neck surgery. Otolaryngol Clin North Am. 1994;27:203–209.[PubMed]

2. Straatsma BR, Allen RA, Hale PN, Gomez R. Experimental studies employing adhesive compounds in ophthalmic surgery. Trans Am Acad Ophthalmol Otolaryngol. 1963;67:320–334.[PubMed]

3. Ellis RA, Levine AM. Experimental sutureless ocular surgery. Am J Ophthalmol. 1963;55:733–742.

4. Erbil H, Sinav S, Süllü Y, Kandemir B. An experimental study on the use of fibrin sealants in strabismus surgery. Turk J Pediatr. 1991;33:111–116.[PubMed]

5. Leonard F, Kulkarni RK, Brandes G, et al. Synthesis and degradation of poly (alkyl α-cyanoacrylates) J Appl Polym Sci. 1966;10:259–272.

6. Toriumi DM, Raslan WF, Friedman M, Tardy ME. Histotoxicity of cyanoacrylate tissue adhesives. A comparative study. Arch Otolaryngol Head Neck Surg. 1990;116:546–550.[PubMed]

7. Maw JL, Quinn JV, Wells GA, et al. A prospective comparison of octylcyanoacrylate tissue adhesive and suture for the closure of head and neck incisions. J Otolaryngol. 1997;26:26–30.[PubMed]

8. Bernard L, Doyle J, Friedlander SF, et al. A prospective comparison of octyl cyanoacrylate tissue adhesive (dermabond) and suture for the closure of excisional wounds in children and adolescents. Arch Dermatol. 2001;137:1177–1180.[PubMed]

9. Nahas FX, Solia D, Ferreira LM, Novo NF. The use of tissue adhesive for skin closure in body contouring surgery. Aesthetic Plast Surg. 2004;28:165–169.[PubMed]

10. Singer AJ, Hollander JE, Valentine SM, et al. Stony Brook Octylcyanoacrylate Study Group. Prospective, randomized, controlled trial of tissue adhesive (2-octylcyanoacrylate) vs standard wound closure techniques for laceration repair. Acad Emerg Med. 1998;5:94–99.[PubMed]

11. Fogle JA, Kenyon KR, Foster CS. Tissue adhesive arrests stromal melting in the human cornea. Am J Ophthalmol. 1980;89:795–802.[PubMed]

12. Leahey AB, Gottsch JD, Stark WJ. Clinical experience with N-butyl cyanoacrylate (Nexacryl) tissue adhesive. Ophthalmology. 1993;100:173–180.[PubMed]

13. Lee JY, Kim BY, Kim TY. The results of cyanoacrylate glue application for corneal perforation and impending perforation. J Korean Ophthalmol Soc. 2003;44:2735–2741.

14. Bloomfield S, Barnert AH, Kanter PD. The use of Eastman 910 monomer as an adhesive in ocular surgery. I. Biologic effects on ocular tissues. Am J Ophthalmol. 1963;55:742–748.[PubMed]

15. Hong MA, Rapuano CJ. Management of corneal perforations. In: Krachmer JH, Mannis MJ, Holland EJ, editors. Cornea. St Louis: Mosby; 1997. p. 1818.

16. Kim YM, Gupta BK. 2-Octyl cyanoacrylate adhesive for conjunctival wound closure in rabbits. J Pediatr Ophthalmol Strabismus. 2003;40:152–155.[PubMed]

17. Coover HN, Joyner FB, Sheerer NH, et al. Chemistry and performance of cyanoacrylate adhesive. Special Tech Papers. 1959;5:413–417.

18. Pani KC, Gladieux G, Brandes G, et al. The degradation of n-butyl alpha-cyanoacrylate tissue adhesive. II. Surgery. 1968;63:481–489.[PubMed]

19. Refojo MF. Current status of biomaterials in ophthalmology. Surv Ophthalmol. 1982;26:257–265.[PubMed]

20. Alió JL, Gómez J, Mulet E, et al. A new acrylic tissue adhesive for conjunctival surgery: experimental study. Ophthalmic Res. 2003;35:306–312.[PubMed]

21. Quinn J, Maw J, Ramotar K, et al. Octylcyanoacrylate tissue adhesive versus suture wound repair in a contaminated wound model. Surgery. 1997;122:69–72.[PubMed]

22. Quinn JV, Osmond MH, Yurack JA, Moir PJ. N-2-butylcyanoacrylate: risk of bacterial contamination with an appraisal of its antimicrobial effects. J Emerg Med. 1995;13:581–585.[PubMed]

23. Quinn J, Lowe L, Mertz M. The effect of a new tissue-adhesive wound dressing on the healing of traumatic abrasions. Dermatology. 2000;201:343–346.[PubMed]

24. Davis SC, Eaglstein WH, Cazzaniga AL, Mertz PM. An octyl-2-cyanoacrylate formulation speeds healing of partial-thickness wounds. Dermatol Surg. 2001;27:783–788.[PubMed]

25. Singer AJ, Nable M, Cameau P, et al. Evaluation of a new liquid occlusive dressing for excisional wounds. Wound Repair Regen. 2003;11:181–187.[PubMed]

0 Thoughts to “2-Octyl Cyanoacrylate Synthesis Essay

Leave a comment

L'indirizzo email non verrà pubblicato. I campi obbligatori sono contrassegnati *